DNA Sequencing Sample Submission Guidelines
US Sample Preparation
To prepare samples for DNA sequencing, please follow these easy steps:
- For orders with <48 samples, please use 8-strip PCR tubes to streamline preparation and processing. Label your tubes on the side with your initials and sample number. For orders with ≥48 samples, you can receive a discount by using a 96-well PCR plate and arranging the samples vertically (A1 to H1). See the Tubes and Plates section for more details.
- Dilute your sequencing primer to 5 µM (pmol/µl) using water. You will need 5 µl for each sequencing reaction. If you want to use a GENEWIZ Universal Primer, we will add it for you at no charge. Remember that only one primer is used in a sequencing reaction. See the Technical Notes section for tips on designing primers for sequencing.
- For the amount of template needed in each of our DNA Sequencing Services (Pre-Mixed, Pre-Defined, and Custom), please refer to the tables below. Prepare template in 10 µl for each sequencing reaction. Please make dilutions in water or Tris. For best results, do not use Tris-EDTA (TE) because EDTA will inhibit the sequencing reaction.
US Pre-Mixed/Sanger-EZ
In the same tube or Sanger-EZ Tube, mix template (10 µl) and your primer (5 µl) according to the table below. See the Technical Notes section for tips on how to purify PCR products
DNA Type | DNA Length (include vector) |
Template Concentration in 10 µl | Template Total Mass | Your Primer Total Picomoles | Premixed Volume* (Template + Your Primer) |
Plasmids | <6 kb | ~50 ng / µl | ~500 ng | 25 pmol | 15 µl |
6 – 10 kb | ~80 ng / µl | ~800 ng | |||
> 10 kb | ~100 ng / µl | ~1000 ng | |||
Purified PCR Products | <500 bp | ~1 ng / µl | ~10 ng | 25 pmol | 15 µl |
500 – 1000 bp | ~2 ng / µl | ~20 ng | |||
1000 – 2000 bp | ~4 ng / µl | ~40 ng | |||
2000 – 4000 bp | ~6 ng / µl | ~60 ng | |||
> 4000 bp | Treat as plasmid | Treat as plasmid |
*For PCR products purified with an enzymatic cleanup protocol (e.g. ExoSAP-IT), a spectrophotometer cannot be used for accurate DNA quantitation. Reaction components, such as degraded primers and nucleotides, will absorb UV light and inflate the calculated DNA concentration. Instead, use the band intensity on an agarose gel relative to that of mass standards to estimate DNA concentration. Alternatively, a fluorometer, which employs a dye that specifically binds dsDNA, can provide accurate quantitation.
US Pre-Defined
In separate tubes, provide template (10 µl) and your primer (5 µl) according to the table below. See the Technical Notes section for tips on how to purify PCR products. To use a GENEWIZ Universal Primer, simply submit template at the requested concentration in 10 µl.
DNA Type | DNA Length (include vector) |
Template Concentration in 10 µl | Template Total Mass | Template Volume Per Reaction | Your Primer Concentration µM (pmol/µl) | Your Primer Volume Per Reaction |
Plasmids | <6 kb | ~50 ng / µl | ~500 ng | 10 µl | 5 µM | 5 µl |
6 – 10 kb | ~80 ng / µl | ~800 ng | ||||
> 10 kb | ~100 ng / µl | ~1000 ng | ||||
Purified PCR Products | <500 bp | ~1 ng / µl | ~10 ng | 10 µl | 5 µM | 5 µl |
500 – 1000 bp | ~2 ng / µl | ~20 ng | ||||
1000 – 2000 bp | ~4 ng / µl | ~40 ng | ||||
2000 – 4000 bp | ~6 ng / µl | ~60 ng | ||||
> 4000 bp | Treat as plasmid | Treat as plasmid |
DNA Type | DNA Length (include vector) |
Template Concentration in 10 µl | Template Total Mass (recommended) |
Template Volume Per Reaction | Your Primer Concentration µM (pmol/µl) | Your Primer Volume Per Reaction |
Plasmids | Any size | Unknown | At least 500 ng | 10 µl | 5 µM | 5 µl |
PCR Products* | Any size | Unknown | At least 500 ng | 10 µl | 5 µM | 5 µl |
*(US) If you are sending unpurified PCR products, please send 10 µl of undiluted crude product x (# reactions) and provide a gel image of the product to determine concentration.
Shipping Instructions
- GENEWIZ Drop Box or Fridge – Place your samples and a copy of your order form in a GENEWIZ drop box or fridge before the cut-off time. Call 1-877-436-3949 for your nearest GENEWIZ drop-off location. If submitting Sanger-EZ, request courier pickup under “Drop-Off and Delivery Boxes” in your CLIMS account.
- GENEWIZ Courier Service – Request for courier pickup if available at your location. Please call 1-877-436-3949 to find out if a GENEWIZ courier picks up at your site. For San Diego customers within the pickup zone, specify the pickup location when placing your order. Note that GENEWIZ couriers pick up room temperature samples only.
- If a drop box or courier is not available, and for International shipments, ship your samples via overnight delivery service (FedEx if possible) to us at the following location: